Grind carefully around floor boxes and conduits by first locating every buried box and conduit with a scanner, confirming power is locked off, then working around each obstruction with a hand-held cup wheel while the main plate skips over it. Never run the planetary plate directly over a metal box. Keep the dust shroud lowered, hold the grinder flat, and feather the edge so you do not dig into the concrete around the cover. Treat every floor penetration as live until verified, and restore the box flange level after grinding with a thin repair patch.
Floor boxes, junction boxes, and conduit often sit just below the finished slab surface, buried where a planner expects a clean field. A spinning diamond plate can chew through a cover, nick conduit, or crack a box open. Before any grinding, scan the area with a concrete scanner or electronic pipe locator, and mark every box, sump, and conduit run on the floor with spray paint the crew can see from across the room. Some boxes sit only a few millimeters down, so even a light pass can nick the cast iron rim once the diamond crosses the cover edge.
Confirm who owns the circuits. In occupied buildings, floor boxes may feed power to desks, servers, or retail fixtures. Treat every box as energized until a qualified electrician verifies it, labels it, and locks the supply off at the panel before you bring a grinder anywhere near the marked circle.
Use the scan marks to draw a safety circle around each box, typically 150 to 200 mm out from the cover. Within that circle, do not let the big plate cross. Note boxes that sit in walkways, because those need the most careful hand finishing around the rim where foot traffic will later roll.
Let the planetary or walk-behind plate grind up to the marked line but not across the box. Plan passes to end at the circle so you are not starting and stopping over metal. On very small obstacles, raise the shroud and guide the plate edge around the cover rather than tilting the whole machine toward the box by accident. If a box lands mid-pass, do not lift abruptly; coast past the circle and lower the plate again on the far side to keep the floor flat.
Finish the ring around each box with a hand-held angle grinder fitted with a diamond cup wheel, or a dedicated corner grinder. Work slowly around the perimeter, holding the tool flat so you skim the high concrete without gouging near the flange. This is slow detail work; rushing is how chips fly and covers crack open on the first pass. Work in small arcs around the rim rather than pressing one spot, and let the vacuum nozzle follow the cup wheel to catch concrete dust at the box.
Boxes and gaps leak dust into walls and below-grade spaces. Tape plastic over cover openings where safe, keep the HEPA extractor running, and seal any open conduit ends you uncover. Dust in electrical boxes is both a safety hazard and an expensive cleanup bill that the general contractor will not forget on the walkthrough. Where a box is live and cannot be opened, at least tape its cover seams so fine dust cannot creep into the contacts.
After grinding, the box flange should sit flush with the new floor plane. If grinding lowered the slab around the cover, build the flange back up with a rapid-set repair mortar so the new flooring transitions smoothly. Mark the final cover height on the box before you patch, so later flooring does not end up proud or recessed. A flange left too high is a trip hazard; a flange left too low leaves a depression that catches dirt around the cover for years.
The worst mistake is trusting that old drawings show every box. Buildings get retrofitted, and new conduit hides where no map says. Always scan on the day, even if drawings exist. The second is running the plate over a cover just for a second, which cracks box rims and throws hot metal fragments across the floor.
Do not grind an energized box because the cover looks solid. Arc flash and shock are real risks, and a single nick to live conduit can stop the whole building. Lock out, verify, and label before hand work begins anywhere near an active electrical floor box on site.
Can the main grinder run over a sealed floor box? No. Even sealed covers crack or dislodge under a spinning diamond plate, and the hard metal gouges your tooling. Grind up to the marked circle and finish the ring around the box by hand with a cup wheel instead.
How close to the box can I grind? Work to within about 150 mm of the cover with the main plate, then switch to a hand cup wheel for the final ring. Keep the tool flat so you do not undercut the concrete edge beside the flange of the box.