Sealer on polished concrete fails at the interface more often than in the film. A surface polished to 2000 grit has almost no profile for a coating to key into, and that is a design decision, not a defect.
| CSP | Surface | Coating suitability |
|---|---|---|
| 1 | Very smooth, closed | Thin sealers only, high risk |
| 2 | Smooth, slight texture | Most sealers with primer |
| 3 | Light texture, fine aggregate visible | Good for high-build coatings |
| 4-5 | Open texture, coarse aggregate | Not a polished finish |
Mechanical: finish at 400-800 instead of 2000 where a sealer is planned. The satin surface carries enough profile and still reads as polished in most commercial settings.
Chemical: use a primer designed for dense substrates. It provides the bond the profile cannot. Skipping the primer on a 2000-grit floor is the most common cause of delamination.
Apply the sealer system to a 1 m2 panel, cure per the data sheet, then test adhesion with a cross-hatch or a pull-off test. A 1 m2 test costs minutes; a failed 500 m2 application costs the floor.
White edges, blistering in traffic lanes, and sealer peeling in sheets all point to bond failure rather than wear. When that appears, strip the film, re-profile to CSP 2-3, prime, and reapply. Adding another coat over a delaminating film simply adds weight to the sheet that will peel.